700 VA - 3000 VA UPS
User’s and Installation Manual
I
EMC Statements
FCC Part 15
NOTICE: Pursuant to section 15 of the FCC rules, this product has been tested and thereby
complies to the conditions of a Class B (700-1500VA) and Class A (2000-3000VA) digital
device, which have been established for offering sufficient protection against dangerous
interference for installation in a residential area. Installation and use of the equipment should
comply with the instructions provided in order to avoid such interference due to the amount
of radio frequency energy that is radiated and generated by the equipment. In spite of this,
we cannot assure that a certain amount of interference may not occur in some installations. If,
by turning on and off, it can be deduced that your radio or television reception is found to be
influenced by harmful interference from the equipment, it is recommended to use one of the
following preventive measures:
z Place the receiving antenna in a separate location or orientation.
z Ensure a greater distance is achieved between the receiver and the equipment.
z Ensure that your equipment is connected to an outlet on a separate circuit than the
receiver.
z Contact a technician experienced with radio and TV or a dealer for further assistance.
ICES-003
This Class B Interference Causing Equipment meets all requirements of the Canadian
Interference Causing Equipment Regulations ICES–003. Cet appareil numérique de la classe
B respecte toutes les exigences du Reglement sur le matériel brouilleur du Canada.
Declaration of Conformity Request
Units labeled with a CE mark comply with the following standards and directives:
z Harmonic Standards: EN 50091-1-1 and EN 50091-2
z EU Directives:73/23/EEC, Council Directive on equipment designed for use within
certain voltage limits
93/68/EEC, Amending Directive 73/23/EEC
89/336/EEC, Council Directive relating to electromagnetic compatibility
92/31/EEC, Amending Directive 89/336/EEC relating to EMC
The EC Declaration of Conformity is available upon request for products with a CE
mark.
Page view 0
1 2 3 4 5 6 ... 18 19

Summary of Contents

Page 1 - 700 VA - 3000 VA UPS

700 VA - 3000 VA UPS User’s and Installation Manual IEMC Statements FCC Part 15 NOTICE: Pursuant to section 15 of the FCC

Page 2 - SAVE THESE INSTRUCTION

14 5.3 Connection to mains and loads (700 - 3000 VA) The following Input and Output cables come supplied with all models 700 VA, 1000 VA, (option)

Page 3 - 2. System description

16 6. Computer and Alarm connections At the back of the UPS is an interface allowing direct communication with your computer system, the location of

Page 4

18 7. User’s guide to operations Necessary information for operation of the unit is covered in this chapter. Normally the UPS runs automatically

Page 5

20 Status of the UPS, measurements and alarms are all indicated on the LCD screen. Figure 6. Control panel Normal display The UPS status is sho

Page 6

22 Settings LCD display Explanation Selection Factory default 208/220/230/240 V 230V Output Volt.Setting O/P V Setting Select Nominal Voltage 100/1

Page 7 - 5.2 Rear panel views

24 7.5 Trouble shooting Displayed on LCD Audible Alarm Alarm Description What You Should Do Output Overload Two Beeps per second The UPS is overloa

Page 8

26 The following is a step-by-step tutorial for replacing the batteries: 1. The front panel of the UPS can be removed by pushing where the arrows

Page 9

28 OUTPUT Output Voltage: 208/220/230/240 VAC, selectable from LCD panel Voltage regulation: ± 2% Voltage distortion: < 5% THD at full non-line

Page 10

30 Dimensions W x D x H mm 428 x 425 x 84 428 x 425 x 84 428 x 425 x 84 428 x 610 x 84 428 x 610 x 84Weight kg 14.6 17.3 18.1 31.6 33 19” Rack-mou

Page 11

32 Battery Cabinets 700 VA 1000 VA 1500 VA 2000 VA 3000 VA Battery type Lead-acid 7 Ah/12 V Lead-acid 7 Ah/12 V Lead-acid 7 Ah/12 V Lead-a

Page 12

II CONTENTS 1. Introduction...1 2. System description...

Page 13

IV The instructions contained within this safety manual are deemed important and should be closely followed at all times during installation and foll

Page 14

2 Fig.1. Block diagram Efficiency Optimizer function The Efficiency Optimizer function is a new feature for the UPS adding cost effectivene

Page 15 - WARNING!

4 3. Safety Information Information presented here is vital to all personnel and please also read the UPS safety manual. Storage and Transportation P

Page 16 - 9. Technical Specifications

6 Installations with accessories of “Vertical” and “Wall-mounted” types: Please install the vertical and wall-mounted types of units according to the

Page 17

8 Installation with accessories of “Stack” types: Please install the types of units according to the following illustration. Stack installation

Page 18

10 2K~3KVA REAR PANEL 11 RM(1U) 700-1KVA Rear Panel

Page 19 - Terminal Block (optional)

12 RM(2U) 700/1K/1.5KVA Rear Panel 13RM(2U) 2K-3KVA Rear Panel

Comments to this Manuals